Jet Fan Calculator questions
Short answers on what Jet Fan Calculator works out, what it leaves out, its units and what happens to your data. Figures are the engine's output for the app's default inputs unless the answer names another value. The formulas and every limit are on the how it works page.
What does Jet Fan Calculator calculate?
It works out how many jet fans a road tunnel needs to hold the critical air velocity you enter, for a fire anywhere along it. It also shows air density, hydraulic diameter, design velocity, maximum temperature and a fire-location table with temperature, pressure loss, thrust and fans for each location.
How does it choose the required number of jet fans?
The app places the fire at 0, 10, 20 m and so on along the tunnel, and once 0.1 m before the exit. At each place it divides the thrust needed by one fan's useful thrust and rounds up. The required number is the largest of these counts, and it is never below zero.
Does it calculate the critical velocity?
No. Critical air velocity is an input: the app uses the value you enter as the design velocity and does not work it out from the fire or the tunnel. Sonicon's Critical Velocity Calculator is a separate app for that step. With the defaults, 3 m/s gives 6 fans and 4 m/s gives 10.
Does the count include spare fans or fans lost in a fire?
No. The count is the thrust needed divided by one fan's useful thrust, rounded up, with nothing added. It does not add spare fans for maintenance, or replace fans in the fire zone that may stop working in a fire. Add any allowance your design method or project requires yourself.
How does the app reduce a fan's bench thrust?
The app takes the bench thrust you enter and multiplies it by a velocity factor from the fan and hydraulic diameters, 1 − 1.2 × (Df / Dh)², by your installation factor, and by the ratio of average tunnel air density to the fan test density. It does not correct for jet velocity or fan spacing.
Which inputs are not used in the calculation?
Height, width, fan velocity, temperature resistance and power consumption are recorded with your other entries and marked as reference only. Changing them changes nothing in the result. The calculation uses cross section and perimeter for the tunnel, and it does not check a fan's temperature rating against the smoke temperature.
How does tunnel slope change the result?
Slope enters only the fire buoyancy term, over the hot section downstream of the fire. A positive slope lowers the total loss and a negative one raises it; the app does not say which way a positive slope rises. With the defaults, −3 % gives 11 fans; +3 % gives 6, the same as level.
Does it follow PIARC, NFPA 502 or another standard?
No. The app implements one calculation, ported from Sonicon's earlier web calculator, and its formula screen says it implements no named standard. It makes no claim of compliance with PIARC, NFPA 502 or any other standard. Compare its formulas with the method that governs your project, and have a qualified engineer verify the results.
What units does it use?
SI units only: metres, square metres, m/s, pascals, newtons, degrees Celsius, megawatts, kilowatts and kg/m³. Numbers use a dot as the decimal mark, whatever your phone's language. There is no unit switch, so convert imperial values before you enter them.
Does the app send my inputs anywhere?
No. The app has no internet permission, no account, no ads and no analytics. It keeps the numbers you typed in one file on your phone so they are there next time, and Android may include that file in your Google account backup and restore it on a new phone. Details are in the app's section of our privacy policy.