How many jet fans your tunnel needs, worked out on your phone
An offline calculation aid for Android. Enter your tunnel, fire, traffic and fan data; see the jet fan count and the working behind it.
A calculation aid. Results depend on the values you enter and must be verified by a qualified engineer.
What Jet Fan Calculator is
Jet Fan Calculator is an offline Android calculation aid for road-tunnel fire ventilation. You enter ambient conditions, the fire, tunnel geometry, traffic and jet fan data; it works out the thrust needed with a fire at every 10 m along the tunnel and gives the largest fan count, with every formula on a reference screen.
What you enter
The app has 36 fields in five groups, filled in with defaults you can change. Everything is in SI units. Height, width, fan velocity, temperature resistance and power consumption can be recorded too; the app marks them “Reference only. Not used in the calculation.” Your entries are kept on the phone for next time.
-
Ambient conditions
Ambient temperature, tunnel altitude, adverse wind speed and meteorological pressure.
-
Fire
Heat release rate, convection rate and the critical air velocity, which you enter: the app does not calculate it.
-
Tunnel geometry
Cross section, perimeter, length, slope, wall friction, and the entrance and exit loss coefficients.
-
Vehicles
Frontal area, drag coefficient and traffic share for cars, LCVs and HGVs, plus traffic density, PCU factor and lanes.
-
Jet fans
Bench thrust, fan diameter, installation factor and test air density. Gravity sits in this group too; it is used only in the fire buoyancy term.
What you get
The Required Number of Jet Fans is the largest count over all fire locations. Beside it the app shows air density, hydraulic diameter, design velocity and maximum temperature, then a fire-location table every 10 m and once 0.1 m before the exit, with the average temperature downstream of the fire, total pressure loss, thrust and jet fans for each row.
With the default inputs the table has 112 rows. A fire at the entrance needs 5 fans; from 470 m on, 6. The worked example
Required Number of Jet Fans
6
- Air density
- 1.0924 kg/m³
- Hydraulic diameter
- 9.20 m
- Design velocity
- 3.00 m/s
- Maximum temperature
- 81.20 °C
It shows its working
Every formula the calculation uses is on the Formula Reference screen, with its symbols and units. An empty or unusable entry is explained at its field and never turned into zero. A result is marked “Out of date” when you change an input, and a note appears if the car, LCV and HGV shares don't total 100 %.
- Offline: no internet permission, no account and no ads.
- Your entries come back: the app keeps what you typed, and Reset to defaults puts the defaults back after you confirm.
- Desk and site: light and dark themes follow your phone.
- SI units only: metres, m², m/s, pascals, newtons, °C, MW and kg/m³, with a dot as the decimal mark.
- Phones: Android 8.0 or later.
Check before you rely on it
Jet Fan Calculator applies one calculation, ported from Sonicon's earlier web calculator, to the values you enter. It implements no named standard. The critical air velocity is an input, not calculated, and the count adds no spare fans for maintenance or for fans lost in the fire zone. Have a qualified engineer verify every result.
Read every input and limit and the terms for this app.
What happens to your data
Jet Fan Calculator has no internet permission, account, ads or analytics, and we collect nothing from it. The numbers you type are kept in one file on your phone so they are there next time, and Android may copy that file to your Google account backup and to a new phone. Read the full privacy policy.